Colophony or Rosin Based Solder Flux Fume is a known cause of occupational asthma and as such exposure to it should be controlled. An effective method of engineering exposure control is to use local exhaust ventilation (LEV) to extract the fume at source. Personal exposure to solder fume was quantitatively measured in the breathing zone of a manikin, these exposures were then compared to those caused by uncontrolled soldering in order to assess five different LEV systems. The five LEV systems tested were a downdraught bench; an extracted bench top enclosure, a mobile capturing hood, an on-tip extraction system and a bench top fume absorber.

CoSHH regulations require most LEV systems to be thoroughly tested at least once every 14 months. This applies to all oil mist, welding fume, smoke and dust extraction units that you currently have on site. This examination must be undertaken by a competent person and the tests and reports must conform to HSE standards. HSG258 provides the recommended procedures to achieve these statutory requirements.

A comprehensive LEV report will also be produced for each piece of LEV equipment tested. All of our LEV reports include photos and/or schematic diagrams showing all test point locations, which are also clearly identified on the ducting as required by the HSE. This includes the following in line with guidance from HSG258: Following an inspection, our professional LEV consultant will mark the LEV system as a pass or fail. We will also assist you in improving all control measures where necessary.

All Companies and Employers using extraction equipment have legal requirements they must undertake. All equipment must be examined and tested in order to comply with Regulation 9 of the COSHH Regulations. The Employer must make sure that equipment is maintained and in efficient working order and of good repair. A thorough test should be undertaken once every 14 months and in some cases far more frequently. It is also a requirement of the employer to keep a suitable record of the test. All for a period of at least 5 years. This record should also include details of repairs carried out as a result of the test. See extra details on Local Exhaust Ventilation LEV Testing.

The employer decides who to employ or consult and needs to be an ‘intelligent customer’ to get the best result. HSE has produced simple guidance to help the employer choose a supplier when they are considering installing LEV (see HSE leaflet Clearing the air). Suppliers need to prepare their information to respond to this approach.