Dry type electrical transformers supplier factory 2024
Premium dry type electrical transformers manufacturer: Several factors can affect power quality in transmission lines. These include: Load Characteristics: Non-linear loads can generate harmonics that distort the voltage and current waveforms, affecting the power quality. Transmission Line Length: Longer transmission lines have higher impedance, which can cause voltage drops and affect power quality. Faults on the System: Short circuits, ground faults, or equipment failures can lead to voltage sags, swells, or transients, impacting power quality. Switching Operations: The switching on/off of large loads or reactive power compensation devices can cause transient overvoltages that degrade power quality. Grid Interconnections: Interconnections between different power systems can introduce disturbances, affecting the power quality. See more details at dry type transformer suppliers.
Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.
Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.
What is the capacity of the transformer related to? The capacity of the transformer refers to the maximum load electric power that the transformer can bear. The capacity of the transformer is related to the following factors: Input voltage and output voltage: The input voltage and output voltage of the transformer determine the transformation ratio of the transformer, which affects the capacity of the transformer. The higher the input voltage of the transformer and the lower the output voltage, the larger the transformation ratio and the larger the capacity. Load nature: Different loads have different power factors, harmonic content and other characteristics, which affect the capacity of the transformer. For inductive loads, the capacity of the transformer can be appropriately reduced; for nonlinear loads, the capacity of the transformer needs to be appropriately increased.
Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.
Founded in 2002, CANWIN Automatic Equipment Manufacturing Co., Ltd. is one of the largest electrical equipment manufacturers in China. We focus on the R&D for Silicon Steel Sheet Cut To Length Lines, Silicon Steel Sheet Slitting Line, Transformer Foil Winding Machines and other equipment. Adhering to the business route of High-end Manufacturing+ Smart Equipment + Smart Factory, we established the Silicon Steel Sheet Engineering Technology Research Center, Metal Strip Precision Cutting Key Technology & Equipment Engineering Center, and Power Transformer Intelligent Manufacturing Center to improve the shearing precision and speed. We have contributed the upgrading and innovating of global power industry institutions.
Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.
As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. Find extra info at canwindg.com
Digital measurement – Digital measurement of transformers or other components can be conducted, and the measurement results can be called and collected from the process layer and station control layer through digital networks, thus monitoring transformers and other equipment.Status visualization – The operation status of transformers can be visualized and observed in the power grid.Smart grid or other related systems can express the status information of transformer self-detection or information interaction.
Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.
What does the rated value on the nameplate of the transformer mean? The rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer. Usually includes the following aspects: Rated capacity: The rated capacity of a transformer refers to the maximum load electric power that the transformer can continuously supply. For example, a 10MVA transformer means that the transformer’s maximum load can reach 10 megawatts. Rated voltage: The rated voltage of the transformer refers to the design voltage of the transformer. For example, a 220kV/110kV transformer means that the input voltage of the transformer is 220 kV and the output voltage is 110 kV. Rated frequency: The rated frequency of a transformer refers to the power frequency for which the transformer is designed. In China, the power frequency is usually 50Hz. Short-time withstand current: The short-time withstand current of a transformer refers to the maximum current value that the transformer can withstand in a short period of time. For example, the short-term withstand current of a transformer is 50kA, which means that the transformer can withstand an instantaneous current of up to 50 kA.